Offline
when we push the B&G MOB button, the MOB active mark is not being passed by Actisense NGT-1 to Expedition
I have MOB selected in Instruments - > actisense - > settings -> N2K PGNs -> RX
is there something else i need to do?
Last edited by us7070 (6/16/2022 8:08 am)
Offline
Do you kow which (if any) PGN it is supposed to send? I suspect it doesn't.
Offline
No - I don't know which PGN the H5000 is supposed to send
Offline
The MOB PGN is 127233, but I don't think it is on the H5000 NMEA 2000 network.
Looking at my notes, the H5000 doesn't send a MOB event over the websocket either but the MFD does.
Offline
Nick wrote:
The MOB PGN is 127233, but I don't think it is on the H5000 NMEA 2000 network.
Looking at my notes, the H5000 doesn't send a MOB event over the websocket either but the MFD does.
So, what I have found is, using an MFD to send the MOB:
with the actisense i did not get anything, and i do not see PGN 127233 in the raw data.
with the websocket connection i got a pop up in Exp that said "MOB activated No Position Data", I checked Marks, and there was no MOB mark.
Offline
That would suggest Exp doesn't have a valid position.
The MFD doesn't send position with the MOB event.
Offline
Nick wrote:
That would suggest Exp doesn't have a valid position.
The MFD doesn't send position with the MOB event.
pretty sure i did.., but will check