Offline
Hello,
In commissioning a newly installed system I am encountering an issue with Instrument setup in Expedition.
The data source for this system is a Vesper Cortex M1 configured to use the Vessel Network. I can confirm the overarching theory of operation as validated through TZ iBoat on a mobile device using the vessel network.
Cloning these settings, however, does not work in Expedition. Numerous selections have been tried for TCP, UDP, etc. If I connect the device directly to the cortex WIFI, data is available.
Have any users successfully deployed a setup of Cortex-> Vessel Network -> Expedition?
Offline
I think that if you have selected NMEA 0183 AIS as the settings and aren't seeing anything in the raw data window, then one of the settings wont' be correct.